{{ $t('shop.all.spaetbestellservice.hinweis') }}
Fastening type |
on connection plate, Permanently screwed |
Product weight [g] | 3.450 |
Display | Seven segment display |
Permission |
c UL us - Listed (OL), RCM Mark |
CE certificate (see declaration of conformity) |
to EU EMC directive, to EU machinery directive, to EU low voltage directive |
Bearing temperature [°C] | -25 to 70 |
ambient temperature [°C] | 0 to 40 |
Relative humidity | 0 - 90 % |
Protection category |
IP10, IP20 |
Degree of contamination | 2 |
Material information |
LABS containing materials included, RoHs compliant |
Phase nominal operating voltage | 3-phase |
Nominal operating voltage AC [V] | 400 |
Permitted voltage oscillations | ± 10 % |
Network frequency [Hz] | 50 to 60 |
Nominal current [A] | 5,5 |
Network filter | integrated |
Max. intermediate circuit voltage DC [V] | 560 |
Braking resistance [Ohm] | 68 |
Impulse power braking resistance [kVA] | 8,5 |
Nominal voltage logic supply DC [V] | 24 |
Permitted range logic voltage | ± 20 % |
Power input logic supply without parking brake [A] | 1,00 |
Output voltage range AC | 3x 0 - 360 V |
Nominal output current [A] | 5,0 |
Nominal current per phase, effective [A] | 5,0 |
Peak current per phase, effective [A] | 15 |
Max. peak current duration [s] | 5 |
Nominal performance controller [VA] | 3.000 |
Peak performance [VA] | 6.000 |
Output frequency [Hz] | 0 to 1000 |
Parameterising interface |
USB, Ethernet, Parameterising and commissioning |
Fieldbus coupling |
CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus/TCP, PROFINET, Profibus DP |
Communication profile |
DS301/DSP402, FHPP |
Process coupling |
I/O coupling, for 256 mobile sets |
Max. fieldbus transfer rate [Mbit/s] | 1 |
Bus connector |
Sub-D, 9 pin, Plug |
Encoder output interface, properties | Resolution 16384 ppr |
Encoder output interface, function |
Actual value feedback via encoder signals for speed control mode, Target value for downstream switched slave actuator |
Encoder input interface, properties |
EnDat, HIPERFACE, RS422, SINCOS, 3 phase encoder signals |
Encoder input interface, function |
In synchronous mode as a speed preset of the slave actuator, Encoder signal target speed value |
Quantity digital logic inputs | 10 |
Properties logic inputs |
Freely configurable, Galvanically separated |
Work area logic input [V] | 8 to 30 |
Quantity digital logic outputs 24 V DC | 5 |
Properties digital logic outputs |
Galvanically separated, Partially freely configurable |
Max. current digital logic outputs [mA] | 100 |
Quantity analogue target value inputs | 2 |
Properties target value inputs |
Differential inputs, Configurable for speed, Configurable for current |
Work area target value input | ± 10 V |
Impedance target value input [kOhm] | 20 |
Quantity analogue monitor outputs | 2 |
Work area monitor outputs | ± 10 V |
Resolution monitor outputs [Bit] | 9 |
Properties monitor outputs | Short circuit proof |
{{ $t('shop.all.gewicht') }} | 3.450 g / pcs |
{{ $t('shop.display.artikel.zollwarennummer') }} | 85044085 |
{{ $t('shop.all.hersteller') }} | Festo |
{{ $t('shop.all.spaetbestellservice.hinweis') }}